CONTINUOUS DETONATION OF FUEL-AIR MIXTURES IN THE REGIME OF SELF-OSCILLATORY EJECTION OF THE AIR |
4 | |
2011 |
scientific article | 536.8;536.46 | ||
771-773 |
Results of an experimental study of continuous detonation of a hydrogen-air mixture in the flow-type annular combustor 306 mm in diameter in the regime of air self-ejection are reported. The regime of pulsed detonation is also implemented. The domain of existence of continuous detonation in the coordinates «air ejection slot width versus specific flow rate of hydrogen» was found. |
![]() |