MODELING OF FREE VIBRATIONS OF THE RECONSTRUCTED MIDDLE EAR SUBJECTED TO TYMPANOSTAPEDOPLASTY AND THE STAPES FOOTPLATE PERFORATION |
4 | |
2011 |
scientific article | 531.534: 57+61 | ||
527-529 |
A biomechanical model of the reconstructed middle ear subjected to tympanostapedoplasty and the stapes footplate perforation is presented. The basic aim of this study is to clear up the influence of the tangential displacements in an eardrum at the modes and fundamental frequencies of the reconstructed middle ear. The reconstructed tympanic membrane is modeled as a prestressed annular plate. |
![]() |